Attic ventilation sizing calculator
An under-vented attic in Albuquerque hits 160 °F in July and shortens shingle life by 30%. Use the 1/300 rule to size intake + exhaust in seconds.
Without a vapor retarder, IRC R806.2 forces you to the 1/150 ratio (double the venting).
What we see on NM roofs every week.
The ridge short-circuits the boxes and you end up pulling air FROM the boxes down into the attic. Pick one exhaust type.
Exhaust without intake is the #1 attic problem in ABQ. Vent stack pulls conditioned air out of the house instead of hot air out of the attic.
Every re-paint we inspect has 20–40% of soffit NFA blocked with latex. Poke every hole open with a pick.
Slightly more intake than exhaust is ideal — it pressurizes the attic and blocks wind-driven rain intrusion at the ridge.
Insulation blocking the eave is the same as no soffit vents. Foam or cardboard baffles keep the path open.
Recessed cans, bath fans, and top-plate gaps dump humid house air into the attic — no amount of venting fixes that.
A 160°F attic eats shingles for lunch.
“James spotted our ridge/gable short-circuit in ten minutes. We fixed intake and the summer attic dropped 30°.”
ABQ NE Heights homeowner
Under-vented attic showing signs? Let's look before you buy vents.
I'll tell you whether your intake, exhaust, or insulation is the real bottleneck — free walk-around or same-day photo review.
Independent · no crew · 20+ yrs NM roofs · Same-day photo review
Seeing frost on nail tips or drywall staining? Check the ceiling stain leak check first — condensation and roof leaks look almost identical from below.
Attic ventilation in the high desert
- IRC says total net free ventilation area = 1/300 of the attic footprint when intake and exhaust are balanced (roughly 50/50 low + high). Without a vapor barrier or unbalanced venting, code drops you to 1/150.
- Continuous ridge vent almost always wins in NM: quieter, no moving parts to fail, and stays balanced with the soffit intake. Turbines are fine if the ridge line is broken up, but two turbines rarely equal a full ridge run.
- That's condensation, not a leak — warm humid house air hits cold roof deck fasteners. Fix = more balanced ventilation and check bathroom fans are actually ducted outside, not just into the attic.
+What's the 1/300 rule?
+Ridge vent or turbines?
+Why do I have frost on the nail tips in winter?
Keep going
What most folks read nextUnder-vented attic? We fix it during any re-roof at no extra labor.
Book the free on-site inspection, or send a photo and we'll tell you what to do next. No sales pitch — we don't install roofs.